Skip to main content

Table 3 Summary of docking results on 237 targets that have receptor models from I-TASSER with TM-score > 0.8 and binding site error < 8 Å

From: EDock: blind protein–ligand docking by replica-exchange monte carlo simulation

Dataset

Method

RMSD (Å)

Center distance (Å)

Ave RMSD < 5.0 Å

Ave

Med

Ave

Med

DUDE (57)

EDock

5.47

5.79

2.95

2.85

24

DOCK6

7.02

7.09

4.03

3.54

10

Vina

6.91

6.96

3.41

3.16

9

COACH (180)

EDock

4.62

4.28

2.70

2.11

100

DOCK6

7.05

6.89

4.43

4.24

40

Vina

6.18

6.25

3.53

3.31

59

  1. “Ave” and “Med” represent the average and median values respectively. The best performance is highlighted in italic font in each category